Article Details
Id:18097
Product:finPOWER Connect
Type:FIX
Version:3.04.00
Opened:19/04/2021
Closed:20/04/2021
Released:30/06/2021
Job: J026392

Support Information; shows error in Debug window for SQL Server databases

Support Information, including Help About and Error information, no longer includes "OS Physical Memory" for SQL Server database.

Retrieving this information requires the correct permission, either VIEW SERVER STATE or VIEW DATABASE STATE (depending on the SQL Server edition).

If the User doesn't have permission an error shows in the Debug window for SQL Server databases.

The error is "Failed to get SQL Server Operating System Information. Failed to open DataReader. Failed to open DataTable. The module being executed is not trusted. Either the owner of the database of the module needs to be granted authenticate permission, or the module needs to be digitally signed.".