Article Details
Id:12572
Product:finPOWER Connect
Type:FIX
Version:2.02.04
Opened:14/01/2015
Closed:14/01/2015
Released:13/02/2015
Job: J014753

Batches; auto-sequenced Batch Id fails to generate when there are more than 100 already in the sequence

An auto-sequenced Batch Id fails to generate when there are more than 100 values already in the sequence. A message "Failed to create next Auto-sequenced Batch Id." is displayed.

Auto-sequenced Batch Id's are where the default value defined under Global Settings or Transaction Types includes the tag "[SEQ]".

Note, the standard Batch Id default is "[YMD].[Seq]" - so if you process more than 100 batches in one day this may become an issue.